| Model |
Current ratio
|
Max current |
Winding ratio |
Accuracy |
N/W |
| H-CT007-52D |
1000A/1A
|
1200A |
1:1000 |
0.5Class |
1.45KG |
1500A/5A
|
1800A |
1:300 |
0.5Class |
2000A/5A
|
2400A |
1:400 |
0.5Class |
2500A/5A
|
3000A |
1:500 |
0.5Class |
1,Production Room
2,Application
| ♥Single or Three phase electronics energy meter |
| ♥Sub-Metering Accurate Measurement |
| ♥Data Loggers to analyze Building & Machinery Performance |
| ♥Digital Fault Recorders |
| ♥Smart Grid Application Features, Load Center |
| ♥Single or Three Phase Balance Control |
| ♥In-Factory Display, or In-Home Display |
| ♥Inverters for Solar & Wind Turbine Systems |
| ♥Power Measurement Device for PLC |
3,About current transformer
Current transformer provide a simple, inexpensive and yet accurate means of
sensing current flow in power conductors,CT's are designed to handle motor inrush currents,so no extra precaution is needed to monitor motoros, We are available in 5 basic configurations:
3.1),Three phase and single phase energy meter CT's are available from measuring currents 0-120Amps.
| Photos |
Model |
Current ratio |
Coil ratio |
Load resistance |
Accuracy |
 |
H-CT002 |
1(10)A/2mA |
4:2000 |
12.5Ω |
0.1Class |
 |
H-DCT006 |
5(100)A/2mA |
1:2500 |
10Ω |
 |
H-DCT008 |
10(60)A/4mA |
1:2500 |
10Ω |
 |
H-DCT013 |
5(100)A/2mA |
1:2500 |
10Ω |
3.2),PCB layout CT's(H-CT003series) are available from measuring currents 0-100Amps.
| Photo |
Model |
Current ratio |
Coil ratio |
Load resistance |
Accuracy |
 |
H-CT003A |
5(10)A/2.5mA |
1:2000 |
10Ω |
0.1Class |
| 5(30)A/2.5mA |
1:2000 |
10Ω |
 |
H-CT003B |
5(30)A/2.5mA |
1:2000 |
10Ω |
| 5(60)A/2.5mA |
1:2000 |
10Ω |
 |
H-CT003C |
1(6)A/0.5mA |
1:2000 |
100Ω |
| 20(120)A/10mA |
1:2000 |
10Ω |
 |
H-CT003D |
5(30)A/2mA |
1:2500 |
0Ω |
| 10(100)A/5mA |
1:2000 |
10Ω |
3.3),Ringe or ZRTO CT's(H-CT004series) are available from measuring currents 0-4000Amps.
| Photos |
Model |
Current ratio |
Winding ratio |
Accuracy |
Net weight |
 |
H-CT004E-30D |
200/1.5mA |
1:133 |
0.5Class |
≈0.46KG |
 |
H-CT004E-45D |
600A/1A |
1:600 |
0.5Class |
≈0G |
| H-CT004E-65D |
| H-CT004E-80D |
| H-CT004E-100D |
| H-CT004E-120D |
| H-CT004E-150D |
| H-CT004E-200D |
| H-CT004E-300D |
3.4),Split core CT's(H-CT005series) are available from measuring currents 0-5000Amps.
| Photos |
Model |
Current ratio |
Winding Ratio |
Net weight |
 |
H-CT005-6D |
30A/20mA |
1:1500 |
≈16.7G |
 |
H-CT005-10D |
60A/20mA |
1:1500 |
≈68.8G |
| H-CT005-16D |
120A/40mA |
1:3000 |
≈105G |
| H-CT005-24D |
200A/5A |
1:40 |
≈217G |
| H-CT005-36D |
600A/5A |
1:120 |
≈347.7G |
| H-CT005-48D |
1000A/5A |
1:200 |
≈754G |
3.5),Clamp on CT's(H-CT007series) are available from measuring currents 0-2500Amps.
| Photos |
Model |
Current ratio |
Winding Ratio |
Accuracy |
 |
H-CT007-8D |
10A/1V |
1:1000 |
≈148.8G |
 |
H-CT007-12D |
100A/20mA |
1:5000 |
≈208G |
| H-CT007-20D |
250A/250mA |
1:1000 |
≈310G |
| H-CT007-50D |
1000A/1A |
1:1000 |
≈500G |
| H-CT007-52D |
1000A/1mA |
1:1000 |
≈670.5G |
| H-CT007-52R |
2000A/5A |
1:400 |
≈1.45KG |
| H-CT007-125D |
2500A/5A |
1:500 |
≈1.5G |
4,About Rogowski coil.
| Rogowski coils have been used for the detection and measurement of electric currents for decades. They are based on a simple principle: an "air-cored" coil is placed around the conductor in a toroidal fashion and the magnetic field produced by the current induces a voltage in the coil. The voltage output is proportional to the rate of change of current. This voltage is integrated, thus producing an output proportional to the current.By using precision winding techniques, especially developed for the purpose, the coils are manufactured so that their output is not influenced by the position of the conductor within the toroid, and to reject interference from external magnetic fields caused, for example, from nearby conductors.Basically, a Rogowski coil current measuring system consists of a combination of a coil and conditioning electronics.Rogowski coil current transducers are used for the AC measurement. |
 |
5,Latching relay and motor relay for single phase or three phase electronics energy meter.
| Photos |
Model |
Current range |
Coil |
With CT or Shunt |
|
|
HR120-80A |
80A 250VAC |
Single coil |
Shunt |
|
|
HR304-120A |
120A 250VAC |
Single coil |
H-DCT008 10(120)A/4mA |
6,Mangaese shunt for single phase or three phase electronics energy meter.
| Photos |
Model |
Resistance value |
Current Rang |
Marks |
 |
HS07-120 |
120Mili Ohm |
0-100A |
ODM |
 |
HS27-100 |
0 |
0-100A |
ODM |
7,Mechanical counter for single phase or three phase electronics energy meter.
8,Shipment.