• CT with 5 (40) a
  • CT with 5 (40) a
  • CT with 5 (40) a
  • CT with 5 (40) a
  • CT with 5 (40) a
  • CT with 5 (40) a

CT with 5 (40) a

Application: Electronic, Instrument, Position Sensor, Audio, Lighting
Type: Current Transformer
Phase: Single
Operation Condition: Indoor
Usage: Measurement
Winding Form: Single Layer & Tightly Wound Type
Samples:
US$ 1.35/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory, Group Corporation

Basic Info.

Model NO.
H-CT003C
Insulating Medium
Epoxy Resin
Installation
Penetration Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Rate Current
5A
Max Current
40A
Output
5mA
Coil Ratio
1:1000
Burden Resistance
10 Ohm
Accuracy
0.1class
Pin Lenght
5mm
Transport Package
Standard Export Carton
Specification
39*14MM
Trademark
E-power
Origin
China
HS Code
8504311000
Production Capacity
100, 000PCS Per Months

Product Description


1,About Current transformers series

   Current transformer provide a simple, inexpensive and yet accurate means of
sensing current flow in power conductors. They are available in 5 basic configurations:

1.1,Three phase and single phase energy meter CT's are available from measuring currents 0-120Amps.
CT with 5 (40) a
  Jiaxing Haihan Electron Co.,LTD supply to ODM High ratio vertical current transformers are avalable in a wide range of sizes and materials to meet any AC current sensing needs,our general purpose designs are made from the highest quality silicon steel cores available,and meet most of the common AC current measurement needs, magnetics offers DC immune models that are designed to provide sensing of AC current where DC offsets also exist,all products are offered in standard sizes,with the most popular turns rations



1.2,PCB mount (H-CT003 series) Core CT's are available for measuring currents from 0 to 150 Amps.
CT with 5 (40) a
CT with 5 (40) a
CT with 5 (40) a



1.3, Ring/ZERO(H-CT004 series) Core CT's are available for measuring currents from 0 to 5000 Amps.
CT with 5 (40) a
    Jiaxing Haihan Electron Co.,LTD supply to High ratio vertical current transformers are avalable in a wide range of sizes and materials to meet any AC current sensing needs,our general purpose designs are made from the highest quality silicon steel cores available,and meet most of the common AC current measurement needs, magnetics offers DC immune models that are designed to provide sensing of AC current where DC offsets also exist,all products are offered in standard sizes,with the most popular turns rations.


1.4, Clamp on Core CT's(H-CT007 series) are available for measuring currents from 0 to 5000Amps.
    Jiaxing Haihan Electron Co.,LTD supply to High ratio vertical current transformers are avalable in a wide range of sizes and materials to meet any AC current sensing needs,our general purpose designs are made from the highest quality silicon steel cores available,and meet most of the common AC current measurement needs, magnetics offers DC immune models that are designed to provide sensing of AC current where DC offsets also exist,all products are offered in standard sizes,with the most popular turns rations.
CT with 5 (40) a

1.5,BH (H-CT021 series) Core CT's are available for measuring currents from 0 to 6000 Amps.
CT with 5 (40) a
     Jiaxing Haihan Electron Co.,LTD supply to High ratio vertical current transformers are avalable in a wide range of sizes and materials to meet any AC current sensing needs,our general purpose designs are made from the highest quality silicon steel cores available,and meet most of the common AC current measurement needs, magnetics offers DC immune models that are designed to provide sensing of AC current where DC offsets also exist,all products are offered in standard sizes,with the most popular turns rations.



2,About Current transformers accuracy
 
   A CT is most accurate at rated current with a low burden (load). Accuracy decreases
with increased burden (load) or low line current. In sizing CT's the conductor size and
distance is important. Improper sizing of current transformers or long secondary
conductor runs with undersized cable can result in poor accuracy.

3,Summary
 

  CT's are inexpensive, accurate devices for monitoring current. If properly sized and installed, they will give

many years of trouble free service with no adjustments to make,Call Mr Yomaychen for help with your specific

applications,thank you so much for your cooperation.

4,Model H-CT003series for PCB board.

4.1,Datesheet
CT with 5 (40) a
4.2,Photos show

CT with 5 (40) aCT with 5 (40) aCT with 5 (40) aCT with 5 (40) a



https://haihanelectron.en.made-in-china.com/contact-info.html

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory, Group Corporation
Management System Certification
ISO 9000, QC 080000
OEM/ODM Availability
Yes