Customization: | Available |
---|---|
Application: | Power, Electronic, Instrument, Lighting, Rectifier, Audio, Power Meter |
Phase: | Three |
Still deciding? Get samples of US$ 42.5/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Current range |
0-100KA AC |
Output sugnal(di/dt) |
144mV/1000A @60Hz 120mV/1000A @50Hz |
Accuracy |
0.5% of reading |
Linearity(10%-100% range) |
±0.2% of reading |
Bandwidth(-3dB) |
2Hz to 100KHz |
Internal resistance |
80±10% Ω/400mm |
Output sensitivity tolerance |
±2% |
Max response time(10%-90%) |
1us |
Phase error |
≤1% |
Operation temperature |
-20 to +70 degree celsius |
Measured bus | ±1% maximum on closing unit |
Ext field influence | ±0.5% maximum |
Temperature sensitivity(Max) | ±0.07% per ºC |
Coil&Cable |
Thermoplastic rubber Flame retardant UL 94 V-0 Rated |
Couplings |
PA6 UL 84 V-O Rated |
Color |
Black,Yellow,Red,Green and Blue |
Shieled |
100% coil,100%output cable |